Eagle Speed

Overview

Eagle Speed is an acrylate polymer antifouling paint with fine and specialty chemicals consisting of Zinc or Copper Pyrithione. These may be combined with organic biocides which act as boosters. Its hydrolysis mechanism provides long-lasting antifouling protection and incomparable hull performance. This coating includes a very stable, fine polishing control mechanism for optimal performance. It is suitable for application on approved primers and tie coats present on aluminum and carbon steel substrates. Compliant with IMO Antifouling System Convention AFS/CONF/26. Excellent static performance and excellent recoat ability. High volume solids for a hydrolysis type antifouling Eagle Speed HS displays very good compatibility with various well known producers.

Purpose

Designed as a premium solution for vessels trading at a low speed with low activity, where the focus is maintaining speed and schedule. The product is designed for long service periods and is applied to the submerged hull in newbuilding and drydocking. It can be used up to 90 months as a part of a complete coating system.

Properties

Sheen: Matte

Color: Light Red, Dark Red

Solids: 52 ± 2

Coverage: 6.00 sq. m/L at 100 microns dry

Thickness: 75-175 microns dry, 130-300 microns wet

Flashpoint: 25 ± 2 °C

VOC: 385.00 g/L (material as into the container)

Application Data

Mixing Ratio: Single-pack product which should be stirred thoroughly by a stirring machine before it's application.

Thinner: Not recommended. The material is ready for use. Under special conditions use Thinner PH 400, max 5% by volume.

Painting Method: Airless spraying recommended. Tip range 0.46mm-0.66mm and 0.66-0.79, blowing pressure no less than 141kg/cm2 (2000psi). Thinner may be required. Use proper equipment and comply with safety precautions in accordance with the selected method and work environment. Emergency contact numbers are available worldwide upon any request.

Cleaning: Power tool cleaning and Cleaners with Thinner PH 400.

Readiness Time: The material is ready for use.

Drying and Over-Coating Conditions

Eagle Speed.JPG

Coating Specification

Eagle Speed HS A/F should always be applied under our recommended coating system. In order to ensure strong adhesion and quality A/F performance, the surface should be dry and free from contamination by any existing layers of PhilaDur, Phila VIN/CL, link coat/sealers or various A/F's. Application must comply with the specific recommendations and provisions of the PhilaCoatings Technical Department. Any liability is limited to the quantity and value of the A/F provided, assuming prior approval in writing by Philadelphia Coatings LLC.

Surface Preparation

All surfaces should be clean, dry and free from contamination. A high pressure freshwater wash should be applied prior to the application of the coating. For other surface treatments, please consult with Phila Coatings (USA) Inc.

Storage

Circa 24 months at 20°C, stored at dry, shaded and ventilated condition. The container/paint, must be kept sealed and away from heat and ignition.

Pack Size

Standard packing of 5,3 Gal. (20 Lit) pail. If other packing specifications are needed, please consult with Philadelphia Coatings LLC.

Health and Safety

Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read carefully and conform to precautions on MSDS and packing vessels. To avoid eye and skin contact, tools such as gloves, goggles and face mask etc. should be used during work with product (proper safety measures should be taken according to construction methods and circumstances). All work with the product must be carried out according to all relevant national health, safety and environment standards and codes. This product is for professional use only.

Limitation of liability

All information is given for guidance only and is subject to regional variation depending upon local climate and environmental condition. An excessive film thickness delays the final curing and creates sagging. Over coating interval will increase with the number of paint layers and the thickness of the paint film. For recommended paints at special circumstances, please consult with our Philadelphia Coatings LLC. Apply in good weather. The relative humidity must not exceed 80% temperature of the surface to be coated must be at least 3°C above the dew point. All data from the tests is obtained under lab conditions, so Philadelphia Coatings LLC won’t bear any liabilities from the condition whether the data could reflect the objective status of the actual application circumstance or not.

Disclaimer

The information in the product manual is based on our experiences from tests and practice. For the application without our knowledge, we could only make sure that our products themselves are warranted. We may modify the data in this product manual according to our continuous development and experience accumulation without advanced notice.