PhilaDur Shop Primer PHE 70

Overview

A zinc-free shop primer to protect blasted steel surfaces before the application of topcoat systems. Excellent corrosion resistance, short over coating interval, excellent adhesion to blasted steel, excellent abrasion resistance. PhilaDur shop primer PHE 70 is very compatible with various well-known producers.

Purpose

Anticorrosive shop primer for steel pretreatment during fabrication and assembly, so shop primer should be applied using automatic blasting/spraying equipment.

Properties

Sheen: Matte

Color: Oxide Red

Solids: 28 ± 2

Coverage: 11.20 sq. m/Lit at 25 microns dry / 90 microns wet

Thickness: 25 - 50 microns dry

Flashpoint: Mixed product > 7 °C

VOC: 626.40 g/Lit (material as into the container)

Application Data

Mixing Ratio: Basis 3 part per/volume, Curing Agent 1 part/volume

Thinner: Not recommended. The material is ready for use, under special conditions use Thinner for Epoxy PH 300, max 5% by volume.

Painting Method: Airless spraying is our recommendation, brush and spray follows. Tip range 0.28mm-0.33mm, blowing pressure shouldn’t be less than 153kg/cm2 (2200psi). Additional thinner may be required. Use proper equipment. Actual safety measures and precautions are very important for the selected method and environment. Emergency Contact Numbers are available world wide upon any request.

Cleaning: Power tool cleaning and Cleaners with Universal Thinner

Readiness Time: 30 minutes in suitable temperature

Pot Life: 12 hours at 20 °C

Curing Time: Within 5 days at 23 °C (fully cured)

Drying and Over-Coating Conditions

PhilaDur Shop Primer PHE 70.JPG

Coating Specification

If local temperatures are around freezing there is a long overcoat period. Proper selection of the systems, coating application procedures, and proper surface preparation should be made as per actual existing film esp. over coated epoxy layer. Test in a controlled laboratory for results of design factors, statements and specific recommendations. Always consult with Phila Coatings (USA) Inc. Technical Department.

Surface Preparation

All surfaces should be clean, dry and free from contamination. High pressure fresh water wash should be applied prior to the treatment or of the application. Steel products with mill scale: shot blasting or grit blasting should meet the requirements of Sa1 grade in Sweden derusting standard at least. Steel products without mill scale: to be ground by dynamic tools to meet the requirements of St3 grade in Sweden derusting standard. Steel products painted with plant primer: use slight grit blasting or dynamic tools to carry out secondary surface preparation to meet the requirements of St3 grade in Sweden derusting standard. For other surface treatments, please consult with Phila Coatings (USA) Inc. Technical Department.

Storage

Circa 18 months at 25°C, stored at dry, shaded and ventilated condition. The container/paint must be kept sealed and away from heat and ignition.

Pack Size

Basis 4 Gal. (16 Lit) drum, agent 1 Gal (3,785 Lit) drum. If other packing specifications are needed, please consult Phila Coatings (USA) Inc.

Health and Safety

Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read carefully and conform to precautions on MSDS and packing vessels. To avoid eye and skin contact, tools such as gloves, goggles and face mask etc. should be used during work with product (proper safety measures should be taken according to construction methods and circumstances). All work with the product must be carried out according to all relevant national health, safety and environment standards and codes. This product is for professional use only.

Limitation of liability

All information is given for guidance only and is subject to regional variation depending upon local climate and environmental condition. An excessive film thickness delays the final curing and creates sagging. Over coating interval will increase with the number of paint layers and the thickness of the paint film. For recommended paints at special circumstances, please consult with our Phila Coatings (USA) Inc. Apply in good weather. The relative humidity must not exceed 80% temperature of the surface to be coated must be at least 3°C above the dew point. All data from the tests is obtained under lab conditions, so Phila Coatings (USA) Inc. won’t bear any liabilities from the condition whether the data could reflect the objective status of the actual application circumstance or not.

Disclaimer

The information in the product manual is based on our experiences from tests and practice. For the application without our knowledge, we could only make sure that our products themselves are warranted. We may modify the data in this product manual according to our continuous development and experience accumulation without advanced notice.