PhilaSeal PHE 06/09

Overview

Two-pack polyamide cured vinyl/acrylate epoxy based coating, tie coat/sealer between epoxy primers and antifouling systems. Can be used as tie coat for a wide range of topcoats. An acrylic/vinyl epoxy formulated to protect and be the intermediary tie coat for antifouling or various topcoats. Excellent direct to metal applications and corrosion resistance. Outstanding toughness and durability. Ideal for use on all similar surfaces where a heavy duty coating is required. Suitable over various primers on carbon steel, galvanized and stainless steel substrates. It can be applied at sub zero surface temperatures. PhilaSeal PHE 06/09 displays very good compatibility with various well known producers.

Purpose

Tie coat sealer for a wide range of PhilaCoatings antifouling products. Can be used as primer for outside hull, superstructure, decks, machinery and other steel surfaces. Do not mix with other colors, paints or solvents.

Properties

Sheen: Semi Glossy

Color: Redbrown, Gray, other colors

Solids: 63 ± 2

Coverage: 6.40 m2/Lit at 80 microns dry / 173 microns wet

Thickness: Over 100 microns dry by 1 coat

Flashpoint: 27 °C

VOC: 364.00 g/Lit (material as into the container)

Application Data

Mixing Ratio: Basis 5 part per/volume, Curing Agent 1 part/volume.

Thinner: Not recommended. The material is ready for use, under special conditions use Thinner for Epoxy PH 300, max 5% by volume.

Painting Method: Airless spraying is recommended. Tip range between 0.48mm-0.66mm (21 Thou). Blowing pressure shouldn’t be less than 141kg/cm2 (2000psi). It may be required to add thinner. Use proper equipment and comply with safety precautions in accordance with the selected method and work environment. Emergency contact numbers are available worldwide upon any request.

Cleaning: Power tool cleaning with Universal Thinner PH-400.

Readiness Time: 15 minutes in a proper temperature.

Pot Life: 2 hours at 23°C

Curing Time: Within 3 days at 23°C (fully cured).

Drying and Over-Coating Conditions

PhilaSeal PHE 0609.JPG

Coating Specification

Long overcoat period if temperatures are around freezing point. Proper selection of the systems, coating application procedures and surface preparation are made depending on actual existing film. Best specific design factors and conditions are tested in a controlled laboratory. Consult with Philadelphia Coatings LLC Technical Department before and throughout testing process.

Surface Preparation

All surfaces should be clean, dry and free from contamination. High pressure freshwater wash should be conducted prior to the application. Steel products with mill scale: shot blasting or grit blasting should meet the requirements of Sa1 grade in Sweden de-rusting standard at least. Steel products without mill scale: to be ground by dynamic tools to meet the requirements of St3 grade in Sweden de-rusting standard. Steel products painted with plant primer: use slight grit blasting or dynamic tools to carry out secondary surface preparation to meet the requirements of St3 grade in Sweden de-rusting standard. For other surface treatments, please consult with Philadelphia Coatings LLC.

Storage

Circa 18 months at 25°C, stored at dry, shaded and ventilated condition. The container/paint, must be kept sealed and away from heat and ignition sources.

Pack Size

4 Gal. (15 Lit) pail, agent 0.8 Gal (3,785 Lit) tin. If other packing specifications are needed, please consult with Philadelphia Coatings LLC.

Health and Safety

Prior to use, obtain, consult and follow the Material Safety Data Sheet for this product concerning health and safety information. Read carefully and conform to precautions on MSDS and packing vessels. To avoid eye and skin contact, tools such as gloves, goggles and face mask etc. should be used during work with product (proper safety measures should be taken according to construction methods and circumstances). All work with the product must be carried out according to all relevant national health, safety and environment standards and codes. This product is for professional use only.

Limitation of liability

All information is given for guidance only and is subject to regional variation depending upon local climate and environmental condition. An excessive film thickness delays the final curing and creates sagging. Over coating interval will increase with the number of paint layers and the thickness of the paint film. For recommended paints at special circumstances, please consult with our Philadelphia Coatings LLC. Apply in good weather. The relative humidity must not exceed 80% temperature of the surface to be coated must be at least 3°C above the dew point. All data from the tests is obtained under lab conditions, so Philadelphia Coatings LLC won’t bear any liabilities from the condition whether the data could reflect the objective status of the actual application circumstance or not.

Disclaimer

The information in the product manual is based on our experiences from tests and practice. For the application without our knowledge, we could only make sure that our products themselves are warranted. We may modify the data in this product manual according to our continuous development and experience accumulation without advanced notice.